Omron SYSDRIVE 3G3MV Setup Manual page 61

Sysdrive 3g3mv series multi-function compact inverter
Hide thumbs Also See for SYSDRIVE 3G3MV:
Table of Contents

Advertisement

List of Parameters
Param-
Regis-
Name
eter
ter No.
No.
(Hex)
n019
0113
Acceleration
time 1
n020
0114
Deceleration
time 1
n021
0115
Acceleration
time 2
n022
0116
Deceleration
time 2
n023
0117
S-shape
acceleration/
deceleration
characteris-
tic
Description
Acceleration time: The time
required to go from 0% to 100% of
the maximum frequency.
Deceleration time: The time
Deceleration time: The time
required to go from 100% to 0% of
the maximum frequency.
Note The actual acceleration or
deceleration time is obtained
from the following formula.
Acceleration/Deceleration
time = (Acceleration/Decel-
time = (Acceleration/Decel-
eration time set value) ×
(Frequency reference value)
÷ (Max. frequency)
Used to set S-shape acceleration/
deceleration characteristics.
0: No S-shape acceleration/decel-
eration (trapezoidal acceleration/
deceleration)
1: S-shape acceleration/decelera-
tion characteristic time 0.2 s
2: S-shape acceleration/decelera-
tion characteristic time 0.5 s
3: S-shape acceleration/decelera-
tion characteristic time 1.0 s
Note When the S-shape accelera-
tion/deceleration characteris-
tic time is set, the accelera-
tion and deceleration times
will be lengthened according
to the S-shape at the begin-
ning and end of acceleration/
deceleration.
Chapter 3
Setting
Default
Chan-
range
setting
ges
during
opera-
tion
0.0 to
10.0
Yes
6,000
10.0
Yes
10.0
Yes
10.0
Yes
0 to 3
0
No
Memo