List of Parameters
Param-
Reg-
Name
eter
ister
No.
No.
(Hex)
3-14
Description
16
Accelera-
ON: Acceleration/
tion/Decel-
Deceleration is on
eration-
hold (running at
prohibit
parameter fre-
command
quency)
17
Local or
ON: Local mode
remote
(operated with the
selection
Digital Operator)
18
Commu-
ON: Communica-
nications/
tions input is
remote
enabled.
selection
19
Emer-
The Inverter stops
gency
according to the set-
ting in n005 for inter-
stop fault
ruption mode selec-
(NO)
tion with the emer-
gency stop input
gency stop input
20
Emer-
turned ON.
gency
NO: Emergency stop
stop warn-
with the contact
ing (NO)
closed.
NC: Emergency stop
with the contact
ith th
21
Emer-
opened.
gency
stop fault
Fault: Fault output is
(NC)
ON and reset with
RESET input. Warn-
ing output is ON (no
ing output is ON (no
22
Emer-
reset required).
gency
"STP" is displayed
stop warn-
(lit with fault input
ing (NC)
ON and flashes with
alarm input ON)
23
PID con-
ON: PID control dis-
trol cancel
abled.
24
PID con-
ON: Integral value
trol inte-
reset.
gral reset
25
PID con-
ON: Keeps integral
trol inte-
value on hold.
gral hold
26
Inverter
ON: Displays invert-
overheat-
er overheating warn-
(See
ing warn-
ing (oH3).
note)
ing
Set-
Default
ting
setting
range
g
y
p
t
t
Chapter 3
Chan-
Memo
ges
during
opera-
tion