Omron SYSDRIVE 3G3MV Setup Manual page 67

Sysdrive 3g3mv series multi-function compact inverter
Hide thumbs Also See for SYSDRIVE 3G3MV:
Table of Contents

Advertisement

List of Parameters
Param-
Reg-
Name
eter
ister
No.
No.
(Hex)
Multi-
n056
0138
function
input 7
p
(Input ter-
(
minal S7)
Description
5
Fault reset ON: Fault reset (dis-
abled while RUN
command is input)
Signals to select fre-
6
Multi-step
speed ref-
quency references 1
erence 1
through 16.
7
Multi-step
speed ref-
erence 2
8
Multi-step
speed ref-
erence 3
9
Multi-step
speed ref-
erence 4
10
Inching
ON: Inching fre-
frequency
quency command
command
(taking precedence
over the multi-step
speed reference)
11
Accelera-
See set value 27.
tion/decel-
eration
time
selection 1
12
External
ON: Output turned
base block
OFF
command
(NO)
13
External
OFF: Output turned
base block
OFF
command
(NC)
14
Search
ON: Speed search
command
(Searching starts
(Search-
from n011)
ing starts
from maxi-
mum fre-
quency)
15
Search
ON: Speed search
command
(Search-
ing starts
from pre-
set fre-
quency)
Set-
ting
range
1 to
35,
(
(26
See
S
note.)
34, 35
g
Chapter 3
Default
Chan-
Memo
setting
ges
during
opera-
tion
10
No
3-13

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents