Design
D 5.5-/7.5-kW Inverters
• Loosen the terminal cover screws in the direction of arrows 1.
• Press the left and right sides of the terminal cover in the direction of arrows 2 and lift it in the direction of
arrow 3 as shown in the following illustration.
Note None of the following 200-V models have a terminal cover. Instead, the front cover is used as a
terminal cover.
3G3MV-A2001 (0.1 kW), 3G3MV-A2002 (0.2 kW), 3G3MV-A2004 (0.4 kW), 3G3MV-A2007 (0.75
kW), 3G3MV-AB001 (0.1 kW), 3G3MV-AB002 (0.2 kW), and 3G3MV-AB004 (0.4 kW)
H Removing the Bottom Cover
D 0.2- to 3.7-kW Inverters
• After removing the front cover and terminal cover, press the bottom cover in the arrow 1 direction
based on position A as a fulcrum.