n002
0102
Control
mode selec-
tion
n003
0103
RUN com-
mand selec-
tion
Description
Used to select the control mode of
the Inverter.
0: V/f control mode
1: Vector control mode (open loop)
Note The set value in n002 is not
initialized with n001 set to 8,
9, 10, or 11.
Note Each of the following param-
eters is initialized according
to the preset control mode.
The default setting varies
with the control mode.
n014: Middle output frequency
n015: Middle output frequency
voltage
n016: Minimum output frequency
n017: Minimum output frequency
voltage
n104: Torque compensation pri-
mary delay time constant
n111: Slip compensation gain
n112: Slip compensation primary
delay time constant
Used to select the input method for
the RUN and STOP commands in
remote mode.
0: The STOP/RESET Key on the
digital Operator is enabled.
1: Multi-function input is enabled
through the control circuit termi-
nals in 2- or 3-wire sequence.
2: RS-422/485 communications are
enabled.
3: Input is enabled from the
optional DeviceNet Communica-
tions Unit.
Note The RUN command only
through key sequences on
the Digital Operator is
acceptable in local mode.
Chapter 3
Setting
Default
Chan-
range
setting
ges
during
opera-
tion
0, 1
0
No
0 to 3
0
No
Memo
3-3