List of Parameters
Param-
Reg-
Name
eter
ister
No.
No.
(Hex)
Note Available for 5.5- and 7.5-kW Inverters only.
3-16
Description
The Inverter will not
28
General -
operate with S1 to
purpose
input 1
S7 sensor input if
these functions are
these functions are
29
General -
set. They are used
purpose
when you want sen-
input 2
sors to provide SYS-
MAC information via
MAC information via
30
General -
the Inverter for
purpose
RS422/485 or Option
input 3
Unit communications
(DeviceNet)
(DeviceNet).
31
General -
The status of S1 to
purpose
S7 is constantly re-
input 4
freshed at register
freshed at register
002B regardless of
32
General -
the n050 to n056
purpose
settings.
input 5
Multi-function input
Multi-function input
33
General -
monitoring is a use-
purpose
ful function for Devi-
input 6
ceNet.
34
Up or
Up or down com-
down
mand (set in n056
command
only)
By setting n056 to
34, the set value in
n055 is ignored and
the following setting
are forcibly made.
S6: Up command
S7: Down command
35
Self-diag-
ON: RS-422/485
nostic test
communications self-
diagnostic test (set in
n056 only)
Chapter 3
Set-
Default
Chan-
ting
setting
ges
range
during
opera-
tion
Memo