Chapter 9
Configuring Catalyst 3750-X StackPower
You can also configure a switch connected in a power stack to not participate in the power stack by
setting the switch to standalone power mode. This mode shuts down both stack power ports. This is a
switch parameter and is configurable by entering the stack-power switch global configuration command
followed by a switch number to enter switch stack power configuration mode.

Power Priority

You can configure the priority of a switch or powered device to receive power. This priority determines
the order in which devices are shut down in case of a power shortage. You can configure three priorities
per system: the system (or switch) priority, the priority of the high-priority PoE ports on a switch, and
the priority of the low-priority PoE ports on a switch.
You set port priority at the interface level for powered devices connected to a PoE port by entering the
power inline port priority {high | low} interface configuration command. By default, all ports are low
priority. This command is visible only on PoE ports.
Although the power inline port priority {high | low} command is visible on the Catalyst 3560-X switch
Note
PoE ports, it has no effect because Catalyst 3560-X switches do not participate in stack power.
You configure the priority values of each switch in the power stack and of all high and low priority ports
on that switch by using the power priority commands in power-stack configuration mode. These
commands set the order in which switches and ports are shut down when power is lost and load shedding
must occur. Priority values are from 1 to 27; switches and ports with highest values are shut down first.
The 27 priorities are used to accommodate power stacks connected in a star configuration with the
Note
expandable power supply. In that case there would be nine members (switches) per system with three
priorities per switch. See the hardware installation guide for more information on StackPower star and
ring configuration.
On any switch, the switch priority must be lower than port priorities. and the high priority value must be
set lower than the low priority value. We recommend that you configure different priority values for each
switch and for its high priority ports and low priority ports. This limits the number of devices shut down
at one time during a loss of power. If you try to configure the same priority value on different switches
in a power stack, the configuration is allowed, but you receive a warning message.
The default priority ranges, if none are configured, are 1-9 for switches, 10-18 for high-priority ports,
and 19-27 for low-priority ports.

Load Shedding

Load shedding is the process of shutting down devices in case of power supply, cable, or system failures.
For power stacks in power-sharing mode, there are two types of load-shedding: immediate and graceful.
OL-21521-01
Immediate load shed occurs when a failure could cause the power stack to fail very quickly. For
example, if the largest power supply in the power stack fails, this could cause the stack to
immediately start shutting down powered devices.
Graceful load-shedding can occur when a smaller power supply fails. Switches and powered devices
are shut down in order of their configured priority, starting with devices with priority 27, until the
power budget matches the input power.