Basic Operation of Configuration Software

Monitor Mode

The configuration software can display scanning zone information of the OS32C in real-time without stopping
the machine. The monitor mode can be used by logging on to the OS32C with either operator, maintenance,
or supervisor access level.
To start the monitor mode, select System Monitoring from the Utilities menu. To terminate, follow the same
step and deselect System Monitoring.
Fig. 3-72 System Monitoring
The outmost border indicates a scanning zone of the OS32C on the diagram above. A zone marked in pink
indicates the intruded area in the warning zone 1, a zone marked in yellow indicates the intruded area in the
warning zone 2, while a zone marked in red indicates the intruded area in the safety zone. The zone selected
in Foreground is displayed as purple line. (In this example, Zone 2 and Warning zone 2 are selected)
Under the monitor mode, the OS32C state is displayed on the main tool bar.