Scanner Timeout (Trigger Enabled Mode Only) - Omron V520-LHA7127 User Manual

Miniature high speed ccd fixed position scanner
Table of Contents

Advertisement

Appendix A - Programming Menus & Commands

25. Scanner Timeout (Trigger Enabled Mode only)

These commands, which are only applicable in the Trigger enabled mode, establish the time-out period after
the trigger pulse is received. The time-out period is the same whether the scanner is operating in Single,
Multiple or Continuous Read mode.
Computer Command
(Z7)
Function/Description
Programming Menu
Trigger remains ON
Y0
as long as trigger is pulled
(hardware trigger only)
Y1
1 Second after triggering
Y2
2 Seconds after triggering
Y3
3 Seconds after triggering
Y4
4 Seconds after triggering
Y5
6 Seconds after triggering
Y6
8 Seconds after triggering
Y7
10 Seconds after triggering
START/END
V520-LHA7127
Bar Code Command
-[8-
-Z1-
-Z2-
-Z3-
-Z!-
-Z5-
-Z6-
-Z7-
-Z8-
53