Sensor And I/O Block Replacement; Os32C - Omron OS32C Series User Manual

Safety laser scanner
Hide thumbs Also See for OS32C Series:
Table of Contents

Advertisement

Appendix

Sensor and I/O Block Replacement

Take precautions to prevent dirt, dust or debris from entering the sensor and I/O block connectors. It is
recommended that this be done on a clean workstation as contaminants may degrade the performance of the

OS32C.

When either the sensor block or the I/O block is replaced, the Checkout and Test Procedure on page 125
must be performed.
I/O BLOCK, ASSY
(1)
(3)
(2)
SCREW(x4)
(M4 x 20)
Fig. 7-5 Sensor Block Replacement
Required Tool: 3mm Allen wrench
1.
Remove power from the OS32C.
2.
Remove the four screws and washers that secure the sensor block to the I/O block.
3.
Replace the old sensor block or I/O block with the new one.
4.
Replace the four screws with flat and lock washers in an alternating patterns. It is recommended that
the screws be tightened to a torque of 1.5 - 2.0 N•m (13.28 - 17.1 in•lb).
OS32C
134
User's Manual
WASHER, FLAT(x4)
(4)
WASHER, LOCK(x4)
SENSOR HEAD, ASSY