Configuration Example: Installation on a Machine (2)

An example of installing a cover on the machine with undercut to mount the OS32C is shown below.
The OS32C needs to be installed so that the operator cannot stand between the safety zone and
danger zone.
Set a cover or undercut on the machine as shown in Fig. 4-9 so that the operator cannot stand on the
dead zone.
Machine table
Side View
Machine table
Width of
Danger
zone
danger zone
Safety zone
Top View
Undercut U
SFdistance
Fig. 4-9 Installation on a machine with cover
Put a cover on the OS32C as shown in Fig. 4-9 to cover the dead zone and prevent entry to the
"Undercut U and SFdistance"
The calculation example of safety distance S and SFdistance are the same as Configuration Example:
Installation on a Machine (1).

Configuration Example: Entry Access Protection

An application example for perpendicular approach to the scanning plane is shown below (entry
access protection for a vertical plane protection zone)
•Intrusion body detection protection
Cover
H = 300 mm
The OS32C measurement error Z
Additional error Z
(In this example, Z
Z
distance M
Safety zone that needs setup by the configuration software
S
Recessed mounting on the machine
eliminates the dead zone as shown
in the left figure.
Machine table
(100mm)
1
by reflective background
2
is 0 due to no surrounding wall. See Table 7-2)