Ethernet Cable - Omron OS32C Series User Manual

Safety laser scanner
Hide thumbs Also See for OS32C Series:
Table of Contents

Advertisement

 Tightening Torque
Refer to table below for tightening torque:
Bolt Diameter
M3.5
1.4 N
M5
3.4 N
M6
3.6 N
M8
3.6 N
Table 4-1
 Power Cable
(56)
Fig. 4-36 External dimensional drawing of power cable

Ethernet Cable

44.7
M12
Fig. 4-37 External dimensional drawing of ethernet cable
Tightening Torque
m
m
m
m
L *
Vinyl insulated round cable (diameter max. 10mm) Black
18-core (conductor section area 0.3 mm
insulator diameter max. 1.5 mm)
Standard length L (See *)
NAME PLATE
* SIZES ARE AS BELOW
Model Number
OS32C-CBL-03M
OS32C-CBL-10M
OS32C-CBL-20M
OS32C-CBL-30M
L (CABLE LENGTH)
54.7
RJ45
TWIST TIE
Vinyl insulated round cable (diameter max 6.5mm)
Light blue 4-core (conductor section area 0.34mm
diameter max 1.57mm)
Standard length L (See *)
(Unit : mm)
(90)
2
,
Length in m
3m
10m
20m
30m
* SIZES ARE AS BELOW
Model Number
Length in m
2m
OS32C-ECBL-02M
5m
OS32C-ECBL-05M
OS32C-ECBL-15M
15m
Installation
2
, insulator
OS32C