Status
Other fault
Table 7-1 Diagnostic Code References
OS32C
130
User's Manual
Diagnostic
Description
Code
50
General fault - caused by internal
problem or extreme environmental
condition
51
Mutual interference
52
General fault - caused by internal
problem or extreme environmental
53
condition
54
55
Internal fault - unused
56
General fault - caused by internal
problem or extreme environmental
57
condition
58
59
60
Invalid configuration in unit
72
Incorrect number of active zone set
select inputs (hard fault code after
diagnostic code 70 above persists for
more than 10 minutes)
73
Invalid or undefined zone set select input
combination, but correct number of active
zone set select inputs. (hard fault code
after diagnostic code 71 persists for more
than 10 minutes)
74
Standby input or zone set select inputs
voltage too high
75
Scanner chassis connected to power (24
VDC)
82
Window not detected or entire dust
detection surface is dirty or blocked.
90
Internal temperature fault
Corrective Action
Check environment for excessive
vibration, shock or electrical noise; check
that the window assembly is undamaged
and securely attached. Or consult
factory.
Check for mutual interference with
another scanner (see mounting
considerations on the user manual),
nearby retro reflectors (<1m) or strong
interfering light sources.
Mounting Considerations p.84
Check the environment for electrical
noise sources or interfering light sources.
Or consult factory.
Consult factory.
Check the environment for electrical
noise sources or interfering light sources.
Or consult factory.
Check environment for excessive
vibration or shock.
Reconfigure unit or double check current
configuration.
Check zone set select input wiring and
zone configuration selection.
Check zone set select input wiring and
zone configuration selection.
Check zone set select inputs or standby
input wired at more than system power
(24 VDC).
Scanner chassis should be grounded to
0 VDC
Check that the window is properly
mounted and clean the dust detection
surface.
The scanner internal temperature
exceeds the operating limit. Add more
ventilation.