Read Fault Log - Omron OS32C Series User Manual

Safety laser scanner
Hide thumbs Also See for OS32C Series:
Table of Contents

Advertisement

Basic Operation of Configuration Software

Read Fault Log

There are separate fault logs for the sensor block and for the IO block. Each fault log contains the most recent
100 faults that have occurred. Fault entries are shown with the most recent faults first, so fault entry #1 is the
oldest fault.
To retrieve a fault log:
1.
From the Utilities menu, select Read Fault Log.
2.
Select sensor block or IO Block.
3.
Print or save the error log to a text file.The example below is shown in printed form. When saved to a
text file, the data can later be exported to a spreadsheet.
Omron Scientific Technologies, Inc.
OS32C Configuration Tool - Version 1.7.10
Wednesday, July 31, 2013 - 09:15:31 AM
System Information
Sensor block serial#:
I/O block serial#:
Firmware version:
Model:
Minimum CFG Tool version:
FPGA version:
Compatible FPGA version:
Chronometer (h:mm):
Product series:
Sensor name:
Angular resolution:
Minimum object resolution (cm):
Ethernet Configuration
IP address:
Subnet mask:
Default gateway:
DHCP:
MAC address:
Fault Log - Sensor block
Fault entry 41:
Description: Incorrect number of active zone set select inputs (hard fault code after diagnostic code 70 above persists for
more than 10 minutes).
Countermeasure 1: Check zone set select input connection and wiring and zone selection and zone delay configuration.
Countermeasure 2: Call Tech Support.
Category:
System state:
Firmware version:
Sensor block serial#:
Reference code:
Fault entry 40:
Description: Incorrect number of active zone set select inputs (hard fault code after diagnostic code 70 above persists for
more than 10 minutes).
Countermeasure 1: Check zone set select input connection and wiring and zone selection and zone delay configuration.
Countermeasure 2: Call Tech Support.
Category:
System state:
Firmware version:
Sensor block serial#:
Reference code:
Fault entry 39:
Description: Incorrect number of active zone set select inputs (hard fault code after diagnostic code 70 above persists for
Fig. 3-76 Fault Log
OS32C
78
User's Manual
AS00457S
AS00457B
3.12
OS32C_STANDARD
1.5.0
1.0
1.0
1220:04
OS32C
Scanner at the corner
0.4°
7.0
192.168.40.100
255.255.255.0
192.168.40.5
Enable
00-0C-51-02-00-EE
0x72 ZONE_SELECT_NUM_ACTIVE_FAULT
0x01 CRITICAL_MFG
STOP
2.12
AS00457S
0100-01554
0x72 ZONE_SELECT_NUM_ACTIVE_FAULT
0x01 CRITICAL_MFG
STOP
2.12
AS00457S
0100-01554
0x72 ZONE_SELECT_NUM_ACTIVE_FAULT
Chronometer (h:mm):
849:19
Temperature (°C):
30
FPGA version:
1.0
I/O block serial#:
AS00457B
Chronometer (h:mm):
849:09
Temperature (°C):
30
FPGA version:
1.0
I/O block serial#:
AS00457B