Omron OS32C Series User Manual page 73

Safety laser scanner
Hide thumbs Also See for OS32C Series:
Table of Contents

Advertisement

Where the specified zone shape begins at <starting angle(degrees)> and moves in a counter-
clockwise direction and ends at <ending angle(degrees)>. Specifying a negative angle is permitted.
If the described zone falls within the area between 225˚ and 315˚, the configuration tool will offer to
correct the zone so that the imported zone falls within the minimum and maximum angular
boundaries of the scanner.
Fig. 3-22 Circular segment
Here is an example of a file specifying a circular segment with 2000mm radius starting at 340˚ and
ending at 180˚, It is designated to be written to the safety zone of zone set one.
Line Number
1
32001
2
0
3
0
4
1, 1
5
0
6
2000,340, 180
7
Fig. 3-23 Textfile for circular segment
Basic Operation of Configuration Software