Omron MS-890 User Manual

Omron MS-890 User Manual

Industrial automation scanner

Advertisement

Quick Links

Chipsmall Limited consists of a professional team with an average of over 10 year of expertise in the distribution
of electronic components. Based in Hongkong, we have already established firm and mutual-benefit business
relationships with customers from,Europe,America and south Asia,supplying obsolete and hard-to-find components
to meet their specific needs.
With the principle of "Quality Parts,Customers Priority,Honest Operation,and Considerate Service",our business
mainly focus on the distribution of electronic components. Line cards we deal with include
Microchip,ALPS,ROHM,Xilinx,Pulse,ON,Everlight and Freescale. Main products comprise
IC,Modules,Potentiometer,IC Socket,Relay,Connector.Our parts cover such applications as commercial,industrial,
and automotives areas.
We are looking forward to setting up business relationship with you and hope to provide you with the best service
and solution. Let us make a better world for our industry!
Contact us
Tel: +86-755-8981 8866 Fax: +86-755-8427 6832
Email & Skype: info@chipsmall.com Web: www.chipsmall.com
Address: A1208, Overseas Decoration Building, #122 Zhenhua RD., Futian, Shenzhen, China
  

Advertisement

Table of Contents
loading

Summary of Contents for Omron MS-890

  • Page 1 Chipsmall Limited consists of a professional team with an average of over 10 year of expertise in the distribution of electronic components. Based in Hongkong, we have already established firm and mutual-benefit business relationships with customers from,Europe,America and south Asia,supplying obsolete and hard-to-find components to meet their specific needs.
  • Page 2 MS-890 Industrial Automation Scanner User Manual P/N 84-000890 Rev B...
  • Page 3 All rights reserved. The information contained herein is proprietary and is provided solely for the purpose of allowing customers to operate and/or service Omron Microscan-manufactured equipment and is not to be released, reproduced, or used for any other purpose without written permission of Omron Microscan.
  • Page 4 Preamble ....................3-22 Postamble....................3-23 LRC Status .................... 3-24 Intercharacter Delay ................3-25 Response Timeout ................3-26 Chapter 4 Read Cycle Read Cycle by ESP ................. 4-2 Read Cycle Serial Commands ..............4-2 Multisymbol....................4-3 MS-890 Industrial Automation Scanner User Manual...
  • Page 5 Output Indicators ..................6-9 Beeper....................6-12 Serial Verification................... 6-13 EZ Button ....................6-15 EZ Button Modes................... 6-17 Input 1 ....................6-19 Configurable Output 1 ................6-20 Trend Analysis Output 1 ................ 6-24 Diagnostics Output 1 ................6-27 MS-890 Industrial Automation Scanner User Manual...
  • Page 6 Optoelectric Control ................. 9-8 Advanced Calibration Features ............. 9-14 Calibration by Embedded Menu ............9-17 Chapter 10 Raster/Laser Raster/Laser Setup by ESP..............10-2 Raster/Laser Serial Commands ............10-2 Raster Setup..................10-3 Laser Framing ..................10-7 MS-890 Industrial Automation Scanner User Manual...
  • Page 7 Appendix F Defaulting / Saving / Initializing ..........A-18 Appendix G Position Scanner and Symbol ...........A-21 Appendix H Object Detector ..............A-22 Appendix I Bar Code Configuration ............A-23 Appendix J Test Read Rate ..............A-25 Appendix K Formulas for Number of Decodes ........A-27 MS-890 Industrial Automation Scanner User Manual...
  • Page 8 Introduction Appendix L Operational Tips ..............A-32 Appendix M Interface Standards ............A-33 Appendix N Multidrop Communications ..........A-34 Appendix O Glossary of Terms .............A-39 MS-890 Industrial Automation Scanner User Manual...
  • Page 9 Bold Initial Caps. Host Communications There are four ways to configure and test the MS-890 Industrial Automation Scanner: • EZ Button. • Omron Microscan’s Windows-based ESP (Easy Setup Program), which offers point- and-click ease of use and visual responses to user adjustments.
  • Page 10 Introduction Statement of Agency Compliance The MS-890 Industrial Automation Scanner has been tested for compliance with FCC (Federal Communications Commission) regulations and has been found to conform to all applicable FCC Rules and Regulations. To comply with FCC RF exposure compliance requirements, this device must not be co-located or operate in conjunction with any other antenna or transmitter.
  • Page 11 There are no user serviceable parts in the scanner. Opening the scanner voids the Omron Microscan Systems warranty and could expose the user to laser diode power of up to 7mW.
  • Page 12 The information provided in this certification notice is correct to the best of Omron Microscan’s knowledge at the date of publication. This notice is not to be considered a warranty or quality specification. Users are responsible for determining the applicability of any RoHS legislation or regulations based on their individual use of the product.
  • Page 13 Statement of RoHS Compliance MS-890 Industrial Automation Scanner User Manual...
  • Page 14: Table Of Contents

    Step 11 Save Configuration in ESP.................... 1-13 This chapter is designed to get your MS-890 up and running quickly, using the EZ Button or ESP (Easy Setup Program). Following these steps will allow you to get a sense of the scanner’s capabilities and to test symbol decode performance.
  • Page 15: Step 1 Check Required Hardware

    Always power down BEFORE disconnecting any cables. Item Description Part Number MS-890 Industrial Automation Scanner FIS-0890-0001G, -0002G 9-Pin Configuration Cable 61-000010-02 97-000012-02 Power Supply Object Detector (optional) 99-000004-01 Comm./Serial Cable 61-000034-02 Note: Standalone configuration shown above. MS-890 Industrial Automation Scanner User Manual...
  • Page 16: Step 2 Connect The System

    2. Attach the power supply cable to the 3-pin power connector on the bottom of the scanner. 25-pin host connector Chassis Power ground ground Power Ground 17 Power Power Power +10 to 28 connector VDC (in) Trigger connector MS-890 Industrial Automation Scanner User Manual...
  • Page 17 Connect the System Connecting the MS-890 with Wiring Box 1. Be sure that the wiring box power cord is not plugged in. 2. Connect the scanner to the host computer. 3. Use the 9-pin configuration connector shown below to connect with your computer.
  • Page 18: Step 3 Position Scanner And Symbol

    Important: If using Interleaved 2 of 5 symbols in your application, verify that the number of characters in the symbols being scanned matches the symbol length enabled for the Interleaved 2 of 5 symbology (default is 10 and 6). MS-890 Industrial Automation Scanner User Manual...
  • Page 19: Step 4 Install Esp

    The purpose of ESP is to provide a quick and easy way to set up and configure Omron Microscan products. When the MS-890 is connected to a host computer (Windows Vista, XP, or 2000), ESP can be used to set up communication with a host, configure various firmware settings, and control verification processes.
  • Page 20: Step 5 Select Model

    Step 5 — Select Model When you start ESP, this menu will appear: 1. Select the MS-890 from the menu and click OK. If you do not want to make this selection every time you start ESP, uncheck “Show this dialog at startup”.
  • Page 21: Step 6 Autoconnect

    Note: If your RS-232 host settings cannot be changed to match the scanner’s settings, select Connect... from the Connect menu in the menu toolbar, and then click the Force Connect box when you see the dialog shown at left. MS-890 Industrial Automation Scanner User Manual...
  • Page 22 To copy the scanner’s memory settings into ESP , right-click in the configuration window and select Receive Reader Settings from the dropdown menu. Receive Reader Settings When you select Receive Reader Settings, the settings from the scanner’s memory are sent to ESP. MS-890 Industrial Automation Scanner User Manual...
  • Page 23: Step 8 Calibrate

    1. Check the read range for your particular symbol density. 2. Examine symbol quality and try a different sample symbol. 3. Slightly skew or tilt the symbol or scanner to minimize specular reflection. 4. Verify that the correct symbology is enabled. MS-890 Industrial Automation Scanner User Manual 1-10...
  • Page 24: Step 9 Test Read Rate

    Important: To receive symbol data through the 9-pin configuration port, you must enable the port with the following command: <K146,,1>. 1. Position the symbol in front of an operational MS-890 scanner. 2. Click the Utilities button. 3. Click the Start button in the Read Rate view.
  • Page 25: Step 10 Configure The Scanner In Esp

    Configure the Scanner in ESP Step 10 — Configure the Scanner in ESP To make setup changes to the MS-890, click the App Mode button. The following modes are accessible by clicking the buttons in the first row of App Mode icons: •...
  • Page 26: Step 11 Save Configuration In Esp

    • Send, No Save. Changes will be lost when power is re-applied to the scanner. • Send and Save. This activates all changes in current memory and saves to the scanner for power-on. MS-890 Industrial Automation Scanner User Manual 1-13...