12.
Remove the Exit Module assembly (see page 8-40).
Transfix Load Arm
110 Connector (J250)
to Control Panel Cable
(Not Shown)
Drum Heater
Relay Board
Caution
The Drum Thermal Sensor Cable is routed through the Exit Module. Use
care during removal to avoid damaging the sensor.
13.
Remove the clevis pins securing the Transfix Load Arms to the chassis and
remove the Transfix Load Arms and the Media Release Blade Carriage
Assembly. (See the figure on page 8-28.)
14.
Remove 3 left-handed screws (8500/8550) and washers from the right side of the
Drum Assembly. Note that one of the screws has no washer. The 8400 uses 3
right-handed screws.
15.
Remove 3 screws and washers from the left side of the Drum Assembly.
Service Parts Disassembly
Exit Module Assembly
Media Release
Blade Assembly
Power Control Left Cable
J850
Drum Thermistor
Cable Connector to I/O Board
Drum Heater Cable
Drum Encoder Cable
s8500-091