Drum Maintenance Pivot Plate Assembly
(PL 2.10)
1.
Remove the Drum Maintenance Kit Assembly.
2.
Remove both the Right and Left Side Covers (see page 8-6).
3.
Remove the grounding clip on the right end of the Pivot Plate Shaft.
4.
Remove the KL-clip on the right end of the Pivot Plate Shaft.
5.
Remove the Pivot Plate Shaft.
6.
Disconnect the connector from the I/O Board (black/white).
7.
Feed the cable into the printer while sliding the Drum Maintenance Pivot Plate
out the drum maintenance drawer cavity.
Metal Plate
Replacement Note:
Note
Lightly grease the metal plates on which the cams ride, using a small
quantity of Rheolube 768 grease (P/N 00679900). Also fill the pocket under
the shaft ground with grease.
Service Parts Disassembly
Metal Plate
2
3
1
Grease Points
Grounding Clip
KL Clip
s8500-095
8-33