EverFocus ENVR8304D-8CH User Manual page 120

8-channel plug & play nvr
Hide thumbs Also See for ENVR8304D-8CH:
Table of Contents

Advertisement

ENVR8304D-8CH
RS-485
PTZ Protocol: Select PTZ protocol, choose from the following protocols: Transparent,
Pelco_D, Pelco_P, Everfocus or Samsung. (Note: All cameras on the RS-485 bus must use
the same protocol)
485 ID: This is the ID used by the EKB500 to send commands to the NVR. On an RS-485
connection, every device (PTZ, NVR and controller) must be assigned an unique ID number
between 0 and 127.
Baud Rate: This field is to set the speed at which is used to transmit instruction or
information through the RS-485 port on the NVR. There are eight different speeds: 1200
BPS, 2400 BPS, 4800 BPS, 9600 BPS, 19200 BPS, 38400 BPS, 57600 BPS and 115200 BPS.
Data Bit: This field is the data bit at which you will be transferring. There are two settings
for this option: 8 or 7.
Stop Bit: This field is to set the stop bit for the RS232 connection. There are two different
stop bits, 1 or 2.
Parity: This field is to select the parity level at which you will be connected. You can choose
between None, Odd, or Even parity levels.
Control: One remote control can be used to operate four NVRs. The NVR to be addressed is
selected by pressing the key corresponding to its ID number on the IR Remote control.
Please refer to Appendix C: IR Remote Control.
IR Controller ID: Set up an ID for the NVR and allow the IR remote control to control this
NVR.
111

Advertisement

Table of Contents
loading

Table of Contents