Time Protocols
SNTP: Viewing, Selecting, and Configuring
Changing the SNTP Poll Interval.
Syntax:
For example, to change the poll interval to 300 seconds:
ProCurve(config)# sntp poll-interval 300
Disabling Time Synchronization Without Changing the SNTP
Configuration. The recommended method for disabling time synchroniza­
tion is to use the timesync command.
Syntax: no timesync
For example, suppose SNTP is running as the switch's time synchronization
protocol, with Broadcast as the SNTP mode and the factory-default polling
interval. You would halt time synchronization with this command:
ProCurve(config)# no timesync
If you then viewed the SNTP configuration, you would see the following:
ProCurve(config)# show sntp
Figure 9-10. Example of SNTP with Time Sychronization Disabled
9-14
sntp < 30..720 >
Specifies how long the switch waits between time polling
intervals. The default is 720 seconds and the range is 30 to
720 seconds. (This parameter is separate from the poll inter­
val parameter used for Timep operation.)
Halts time synchronization without changing your SNTP
configuration.
SNTP Configuration
Time Sync Mode: Disabled
SNTP Mode : Broadcast
Poll Interval (sec) [720] : 720