Samples/Time Between Changes
Write security: 3; Read security: 5
This value is the minimum time between bandwidth changes for
this Connection List profile. The range is 0 to 255 seconds. The
default is 60 seconds.
Connection List/Filters
The Express L128T S/T can block packets in and out of a WAN port
by use of the filters. These filters are set up on a per-Connection List
profile basis. They are set up in two steps: 1) define the types of pack-
ets that would be of interest in the Configuration/Security/Filter De-
fines menu, and 2) set up the filter type and combination of defines
that will cause a packet block.
Filters/WAN-to-LAN (In)
Write security: 2; Read security: 5
The packets which come into the Express L128T S/T can be filtered in
three ways:
Disabled (def)
Block All
Forward All
61202070L3-20
Turns off packet input filtering. No incoming
packets are blocked from the WAN.
All incoming packets from the WAN are
blocked except as defined in the Filters/In
Exceptions list.
All incoming packets from the WAN are not
blocked except as defined in the Filters/In
Exceptions list.
Express L128T S/T User Manual
Chapter 3. Terminal Menu Operation
3-55