HRDVS rear
alarm connector
Input 1
Input 2
Internal to HRDVS
Voltage Max = 5 VDC
100 mA max

9-Pin Serial Port Connector Pinouts

Rev 2.00
Figure 3-3
Alarm Inputs Connection
Inputs
To set NO/NC, see
1
Normally Open (NO).
If closed, alarm event is
detected.
2
4
Normally Closed (NC).
If open, alarm event is
detected.
3
External to HRDVS (Add this functionality yourself).
The HRDVS has one alarm output on the rear panel. Contact is always NO.
Figure 3-4
Alarm Output Connection
Output
Normally Open (NO)
Internal to HRDVS
External to HRDVS
The following table describes the 9-pin DTE connector pinouts for the HRDVS, RS-232C
Asynchronous serial port.
Pin #
Name
1
DCD
2
RX
3
TX
4
DTR
5
Ground
6
DSR
7
RTS
8
CTS
9
RI
Setting Alarm
Events, page 67.
5
6
Signal direction (DTE)
17
HRDVS Reference Guide
Document 900.0281