Ipv6 Interface Settings - D-Link DGS-3600 Series User Manual

Layer 3 gigabit ethernet managed switch
Hide thumbs Also See for DGS-3600 Series:
Table of Contents

Advertisement

Enter a name for the new interface to be added in the Interface Name field (if editing an IP interface, the Interface Name will
already be in the top field as seen in the window above). Enter the interface's IP address and subnet mask in the corresponding
fields. Pull the Interface Admin State pull-down menu to Enabled and click Apply to enter to make the IP interface effective. To
view entries in the IPv4 Interface Settings window, click the
window to enter the changes into NV-RAM.
The following fields can be set or modified:
Parameter
Interface Name
IP Address
Subnet Mask
VLAN Name
Interface Admin. State
Secondary
Proxy ARP
Proxy Local ARP
Click Apply to implement changes made.

IPv6 Interface Settings

The following window is used to setup IPv6 interfaces and addresses for the switch.
®
xStack
DGS-3600 Series Layer 3 Gigabit Ethernet Managed Switch
Figure 8- 3. IPv4 Interface Settings – Edit window
Description
This field displays the name for the IP interface or is used to add a new interface to be
created by the user. The default IP interface is named "System".
This field allows the entry of an IPv4 address to be assigned to this IP interface.
This field allows the entry of a subnet mask to be applied to this IP interface.
This field states the VLAN Name directly associated with this interface.
Use the pull-down menu to enable or disable configuration on this interface.
Use the pull-down menu to set the IP interface as True or False. True will set the interface
as secondary and False will denote the interface as the primary interface of the VLAN
entered above. Secondary interfaces can only be configured if a primary interface is first
configured.
Use the pull-down menu to Enable or Disable the proxy ARP state on the IP interface.
Use the pull-down menu to Enable or Disable the proxy local ARP. This function allows
the Switch to respond to the proxy ARP, if the source IP and destination IP are in the
same interface.
NOTE: The Switch's factory default IP address is 10.90.90.90 with a
subnet mask of 255.0.0.0 and a default gateway of 0.0.0.0.
Show All IP Interface Entries
156
hyperlink. Use the Save Changes