4. If no VLANs have been previously configured on the Switch, you can use the default VLAN Name. The default VLAN
contains all of the Switch ports as members. If VLANs have been previously configured on the Switch, you will need to
enter the VLAN Name of the VLAN that contains the port connected to the management station that will access the
Switch. The Switch will allow management access from stations with the same VID listed here.
To use the BOOTP or DHCP protocols to assign the Switch an IP address, subnet mask, and default gateway address:
Use the Get IP From pull-down menu to choose from BOOTP or DHCP. This selects how the Switch will be assigned an IP
address.
The IP Address Settings options are:
Parameter
Description
BOOTP
The Switch will send out a BOOTP broadcast request when it is powered up. The BOOTP protocol
allows IP addresses, network masks, and default gateways to be assigned by a central BOOTP
server. If this option is set, the Switch will first look for a BOOTP server to provide it with this
information before using the default or previously entered settings.
DHCP
The Switch will send out a DHCP broadcast request when it is powered up. The DHCP protocol
allows IP addresses, network masks, and default gateways to be assigned by a DHCP server. If
this option is set, the Switch will first look for a DHCP server to provide it with this information
before using the default or previously entered settings.
Manual
Allows the entry of an IP address, Subnet Mask, and a Default Gateway for the Switch. These
fields should be of the form xxx.xxx.xxx.xxx, where each xxx is a number (represented in decimal
form) between 0 and 255. This address should be a unique address on the network assigned for
use by the network administrator.
Subnet Mask
A Bitmask that determines the extent of the subnet that the Switch is on. Should be of the form
xxx.xxx.xxx.xxx, where each xxx is a number (represented in decimal) between 0 and 255. The
value should be 255.0.0.0 for a Class A network, 255.255.0.0 for a Class B network, and
255.255.255.0 for a Class C network, but custom subnet masks are allowed.
Default
IP address that determines where packets with a destination address outside the current subnet
Gateway
should be sent. This is usually the address of a router or a host acting as an IP gateway. If your
network is not part of an intranet, or you do not want the Switch to be accessible outside your local
network, you can leave this field unchanged.
VLAN Name
This allows the entry of a VLAN Name from which a management station will be allowed to manage
the Switch using TCP/IP (in-band via web manager or Telnet). Management stations that are on
VLANs other than the one entered here will not be able to manage the Switch in-band unless their
IP addresses are entered in the Security IP window (Security > Trust Host). If VLANs have not
yet been configured for the Switch, the default VLAN contains all of the Switch's ports. There are
no entries in the Security IP Management table, by default, so any management station that can
connect to the Switch can access the Switch until a management VLAN is specified or
Management Station IP Addresses are assigned.
Link-Local
This read-only field displays the current link-local address, if applicable.
Address
Global Unicast
This read-only field displays the current global unicast address, if applicable.
Address
Click Apply to implement changes made.
®
xStack
DGS-3600 Series Layer 3 Gigabit Ethernet Managed Switch
NOTE: The Switch's factory default IP address is 10.90.90.90 with a
subnet mask of 255.0.0.0 and a default gateway of 0.0.0.0.