Installing The Hp Smart Array P800; Windows Installation - HP Integrity rx6600 User's & Service Manual

Hp integrity server
Hide thumbs Also See for Integrity rx6600:
Table of Contents

Advertisement

Installing the HP Smart Array P800

On HP Integrity rx6600 servers, the HP Smart Array P800 is supported by HP-UX 1 1i v2 and v3,
OpenVMS 8.3- 1 H1, Windows and Linux operating systems. It should be installed in PCIe slot 3
or 4.
For more information, including configuring and diagnosing array problems, see the HP Smart
Array P800 Controller for Integrity Servers User Guide on the HP website at
go/integrity-iocards-docs.
Click the link for your HP-UX version. Support guides are listed alphabetically in the "User guide"
section.
The installation procedure involves the following steps:
Preparing the server
Installing the controller board.
Connecting the Controller to Other Devices
Completing the adapter installation procedure, including updating the firmware and installing
drivers.

Windows Installation

Procedure 20 Windows Quick Installation Procedure
1.
Power down the server.
2.
Unplug the AC power cord from the power outlet.
3.
Unplug the power cord from the server.
4.
Install the controller hardware
5.
If necessary, install additional physical drives. The number of drives in the server determines
the RAID level that is autoconfigured when the server is powered up (next step)
6.
Power up the server.
7.
Update the controller firmware.
When the firmware update process is complete, the server reboots and runs through a POST
procedure. This POST procedure halts briefly during controller initialization and prompts you
to open ORCA.
8.
Open ORCA
If using a headless console, press the Esc+8 key combination.
Otherwise, press the F8 key.
9.
Configure the logical boot drive, and then exit from ORCA.
10. Load the controller driver from EBSU on the Smart Setup media. (To load the driver, select
Load OEM Boot Drivers in EBSU. For more information about Smart Setup, refer to the HP
Smart Setup Guide on the Smart Setup media.)
1 1. Run Express Setup.
12. When you have finished installing the operating system as directed during the Express Setup
procedure, remove the operating system CD, and then insert the Smart Setup media.
13. Install the Integrity Support Pack.
Procedure 21 Preparing the server
1.
Back up all data.
2.
Close all applications.
3.
Power down the server.
CAUTION:
to be powered down and the last to be powered back up. Taking this precaution ensures that
the system does not erroneously mark the drives as failed when the server is powered up.
4.
Power down all peripheral devices that are attached to the server.
270 Upgrades
In systems that use external data storage, be sure that the server is the first unit
http://www.hp.com/