HP Integrity rx6600 User's & Service Manual page 138

Hp integrity server
Hide thumbs Also See for Integrity rx6600:
Table of Contents

Advertisement

Table 38 Front Panel LED States (continued)
System Health
FLASHING
AMBER OR RED
Off
FLASHING
AMBER OR RED
Off
Steady
Green/Off
Steady Green
Table 39
lists basic entry class troubleshooting conditions and actions.
Table 39 Basic Entry Class Troubleshooting
Step
Condition
1
Chassis appears "dead" -- no
front panel LEDs are on, and
no fans are running.
2a
Server does not power on
after front panel Power button
is momentarily depressed; for
example, is depressed for less
than four seconds.
NOTE:
BMC is running.
2b
Both front panel System
Health and External Health
LEDs are Flashing Amber.
138 Troubleshooting
Internal Health
External Health
Off or Steady
FLASHING
AMBER
Green
FLASHING AMBER
Steady Green
FLASHING AMBER
Steady Green
Steady Green
Steady Green
Steady Green
Steady Green
Steady Green
Steady Green
Action
Nothing is logged for this condition.
1.
For new server installations, review the install procedures.
2.
Verify that the power cords are connected to both the power supplies and
to the AC receptacles.
3.
Verify that AC power, at the proper AC voltage levels, is available to the
receptacles.
4.
Check the front panel connector and the cable to the rest of the system.
5.
If the Power button integrated LED on the front panel remains off, reseat the
power supplies, replace the power cords, and replace the bulk power
supplies, in that order (see
The preceding problem is fixed when the front panel LED states are as follows:
System Health is Off; Internal Health is Off; External Health is Off; and Power
is Steady Amber.
A fatal fault has been detected and logged, attempting to power on the server
(System Health is Off, Internal Health is Off, External Health is Off, and Power
is Steady Amber).
1.
Examine each power supply's LEDs -- if not Steady Green, replace power
supply (see
2.
Examine the iLO 2 MP logs for events related to bulk power supplies (see
This step assumes
"Power Subsystem Behavior" (page
Preceding problem is fixed when BMC's heartbeat LED is Flashing Green, and
the front panel LEDs are as follows: System Health is Off, Internal Health is Off,
External Health is Off, and Power is Steady Green.
A warning or critical failure has been detected and logged after server powers
on (System Health is Flashing Amber, Internal Health is Off /Steady Green,
External Health is Flashing Amber, and Power is Steady Green)
1.
Examine each power supply's LEDs. If not Steady Green, replace power
supply (see
2.
Examine each external fan's LED. If not Steady Green, replace fan(s) (see
"Cooling Subsystem" (page 163)
Preceding problem is fixed when iLO 2 MP logs are read, and the front panel
LED states are as follows: System Health is Off, Internal Health is Off/ Steady
Green, External Health is Steady Green, and Power is Steady Green.
System Power
Basic Entry Class Troubleshooting Table
Step Number
Steady Green
2b/2c in
Steady Green
8b in
Steady Green
3a/3b in
Steady Green
4a, 4b, 4c, and 4d in
Steady Green
8a in
Steady Green
5, 6, and 7 in
"Power Subsystem Behavior" (page
"Power Subsystem Behavior" (page
161)).
"Power Subsystem Behavior" (page 161)
for information).
Table 39
Table 40
Table 39
Table 39
Table 40
Table 39
and
Table 40
161).)
161)).
for information).