View Array Screen
The View Array screen enables you to view the current array configuration. To access the View
Array screen, press Enter on the View Existing Array field from the Select New Array Type screen.
You can perform the following actions on the View Array screen:
To view the next array, press N.
To create a new array, press C.
Array
Identifier
Type
Scan Order
Size (MB)
Status
Bay
Device Identifier
RAID Disk
Hot Spr
Drive Status
reflects the size of the array, not the size of the individual disk. If the
device is part of a three or more disk array, this field is the size that
the disk makes up within the array. When creating a striped array,
the usable size of the array is determined by the number of drives times
the size of the smallest drive in the array. In arrays consisting of
different sized drives, excess space on larger drives are unusable.
Displays the number of this array.
Displays the identifier of this array.
Displays the RAID type.
Displays the scan order of the array.
Displays the size of the array.
Displays the status of the array.
Displays the bay in which devices are located.
Displays the device identifier.
Specifies the devices (disks) that make up an IM array. If RAID Disk is
Yes, the device is part of an IM array, if No, the device is not part of
an IM array. This field is grayed out under the following conditions:
The device does not meet the minimum requirements for use in an
IM array.
The device is not large enough to mirror existing data on the
primary drive.
This disk has been selected as the hot spare for the IM array.
Specifies whether a device is the hot spare for an IM array. If hot spare
is Yes, the device is used as a hot spare for the IM array, if No, the
device is not used as a hot spare for the IM array. Only one hot spare
per IM array is permitted. A hot spare is not required in an IM. A hot
spare can be specified at array creation, or any time after creation,
provided the array is made up of 5 disks or fewer. This field is grayed
out under the following conditions:
The device does not meet the minimum requirements for use in an
IM array.
The array already has a hot spare.
The array is made up of the maximum number of devices (6).
The device isn't large enough to mirror existing data on the
primary. The hot spare drive must be greater than or equal to the
size of any drive in any IM volume.
xxxx
OK
Disk is online and fully functional.
Missing
Disk is not responding.
Failed
Disk has failed.
Initalizing
Disk is initializing.
CfgOffln
Disk is offline at host's request.