3.2.5 Parameter setting method

A parameter value may either be set by updating its parameter number or setting the value digit-by-digit
using the
key.
To write the setting, change it and press the
Example: To change the Pr. 79 "operation mode selection" setting from "2" (external operation mode) to "1"
(PU operation mode)
(For details of Pr.79, refer to page 105.)
Press the
key, to choose the
MODE
parameter setting mode.
#Parameter setting mode
FR-DU04
CONTROL PANEL
MON
EXT
REV
MODE
To 3.2.6 Operation mode
#Current setting
SET
Flicker
key 1.5 seconds.
SET
Most significant
Hz
digit flickers
A
V
SET
PU
FWD
#Setting change
Press for
1.5 s
SET
#Setting write
OPERATION/CONTROL
Middle digit flickers
SET
7 times
or
3 times
0 to 9
When
appears
1) When the [FWD] or [REV] indication is lit,
stop operation by pressing the
or turning off the forward rotation (STF)
or reverse rotation (STR) signal connected
to the control terminal.
2) You cannot set any value that is outside the
parameter setting range. Write a value within
the setting range.
"1" (PU operation mode) has been set in Pr. 79.
If the value and
appears, you did not press the
for 1.5 seconds when writing the value.
Press the
key once, press the
restart the setting from the beginning.
48
Least significant
digit flickers
9 times
or
1 times
SET
0 to 9
MON
EXT
PU
REV
FWD
STOP
key
RESET
do not flicker but
key
SET
key, and
SET
3