4.1.2 List of Parameters Classified by Purposes of Use

Set the parameters according to the operating conditions. The following list indicates purposes of use and
parameters.
Purpose of Use
Switch-over to optimum excitation control operation
Adjustment of acceleration/deceleration time and
pattern
Selection of optimum output characteristic for load
characteristic
Limit of output frequency
Operation over 60Hz
Adjustment of frequency setting signal and output
Adjustment of motor output torque
Adjustment of brake operation
Multi-speed operation
Jog operation
Frequency jump operation
Automatic restart after instantaneous power failure
Optimum acceleration/deceleration within continuous
rating range
To perform commercial power supply
switch-over operation
Timing of magnetic brake operation
Reversible operation according to analog signal
polarity
Sub-motor operation
To make desired output characteristics
Operation via communication with personal computer
Operation under PID control
Advanced PID control
(NA, EC versions only)
To make backlash compensation
To suppress noise
Calibration of frequency meter
Adjustment of digital frequency meter
Display of speed, etc.
Clearing of inverter's actual operation time
Alarm code output selection
Function rewrite prevention
Reverse rotation prevention
To group parameters
To set initial values for parameters
Assignment of input terminal functions
Assignment of output terminal functions
To increase cooling fan life
Motor overheat protection
Automatic restart after alarm stop
Selection of key beep
Inverter reset selection
Parameter numbers which must be set
Pr. 14, Pr. 60
Pr. 7, Pr. 8, Pr. 20, Pr. 21, Pr. 160
Pr. 3, Pr. 14, Pr. 19, Pr. 60
Pr. 1, Pr. 2
Pr. 903, Pr. 905
Pr. 73, Pr. 74, Pr. 902 to Pr. 905
Pr. 0
Pr. 10, Pr. 11, Pr. 12
Pr. 1, Pr. 2, Pr. 4, Pr. 5, Pr. 6, Pr. 15, Pr. 24, Pr. 25, Pr. 26, Pr. 27,
Pr. 160
Pr. 15, Pr. 16
Pr. 31, Pr. 32, Pr. 33, Pr. 34, Pr. 35, Pr. 36
Pr. 57, Pr. 58
Pr. 60
inverter
Pr. 135 to Pr. 139, Pr. 160, Pr. 180 to Pr. 186,
Pr. 190 to Pr. 195
Pr. 42, Pr. 160, Pr. 190 to Pr. 195
Pr. 28, Pr. 73
Pr. 0, Pr. 3, Pr. 7, Pr. 8, Pr. 44, Pr. 45, Pr. 46, Pr. 47
Pr. 100 to Pr. 109
Pr. 117 to Pr. 124, Pr. 160
Pr. 73, Pr. 79, Pr. 128 to Pr. 134, Pr. 160,
Pr. 180 to Pr. 186, Pr. 190 to Pr. 195
Pr. 128, Pr. 130 to Pr. 134, Pr. 180 to Pr. 186, Pr. 190 to Pr. 195,
(Pr. 320 to Pr. 322), Pr. 500 to Pr. 516
Pr. 140 to Pr. 143
Pr. 72, Pr. 240
Pr. 54, Pr. 55, Pr. 56, Pr. 158, Pr. 160, Pr. 900, Pr. 901
Pr. 54, Pr. 55, Pr. 56, Pr. 900
Pr. 37, Pr. 52, Pr. 53, Pr. 160
Pr. 171
Pr. 76
Pr. 77
Pr. 78
Pr. 160, Pr. 173 to Pr. 176
Pr. 199
Pr. 180 to Pr. 186
Pr. 190 to Pr. 195
Pr. 244
Pr. 9, Pr. 71
Pr. 65, Pr. 67, Pr. 68, Pr. 69
Pr. 990
Pr. 75
65