Mitsubishi FR-F500 Instruction Manual page 27

Transistorized inverter
Hide thumbs Also See for FR-F500:
Table of Contents

Advertisement

( 3 ) Cables, crimping terminals, etc.
The following table lists the cables and crimping terminals used with the inputs (R, S, T) L
outputs (U, V, W) of the inverter and the torques for tightening the screws:
FR-F520-0.75K to 55K
Applicable Inverter
Terminal
Type
Screw
Size
FR-F520-0.75K to 2.2K
M4
FR-F520-3.7K
M4
FR-F520-5.5K
M5
FR-F520-7.5K
M5
FR-F520-11K
M5
FR-F520-15K
M6
FR-F520-18.5K
M6
FR-F520-22K
M8
FR-F520-30K
M8
FR-F520-37K
M10
FR-F520-45K
M10
FR-F520-55K
M12
FR-F540-0.75K to 55K
Applicable Inverter
Terminal
Type
Screw
Size
FR-F540-0.75K to 3.7K
M4
FR-F540-5.5K
M4
FR-F540-7.5K
M4
FR-F540-11K
M4
FR-F540-15K
M6
FR-F540-18.5K
M6
FR-F540-22K
M6
FR-F540-30K
M6
FR-F540-37K
M6
FR-F540-45K
M8
FR-F540-55K
M8
Note: 1. The cables used should be 75 C (167 F) copper cables.
2. Tighten the terminal screws to the specified torques.
Undertightening can cause a short or misoperation.
Overtightening can cause the screws and unit to be damaged, resulting in a short or
misoperation.
( 4 ) Connection of the power supply and motor
No-fuse
breaker
The power supply cables
must be connected to R, S, T
L
1
If they are connected to U, V,
W, the inverter will be damaged.
Phase sequence need not be
matched.
For use with a single-phase
power supply,the power supply
cables must be connected to
R and S L
Crimping Terminals
Tightening
Torque
N m
R, S, T
U, V, W
L
, L
, L
1
2
3
1.5
2-4
1.5
5.5-4
5.5-4
2.5
5.5-5
5.5-5
2.5
14-5
2.5
14-5
14-5
4.4
22-6
22-6
4.4
38-6
38-6
7.8
38-8
38-8
7.8
60-8
60-8
14.7
100-10
100-10
14.7
100-10
100-10
24.5
150-12
150-12
Crimping Terminals
Tightening
Torque
N m
R, S, T
U, V, W
L
, L
, L
1
2
3
1.5
2-4 2.5-4
2-4 2.5-4
1.5
5.5-4 4-4
2-4 2.5-4
1.5
5.5-4 4-4
5.5-4 4-4
1.5
5.5-4 4-4
5.5-4 4-4
4.4
14-6 16-6
8-6 10-6
4.4
14-6 16-6
8-6 10-6
4.4
22-6 25-6
14-6 16-6
4.4
22-6 25-6
22-6 25-6
4.4
22-6 25-6
22-6 25-6
7.8
38-8 50-8
38-8 35-8
7.8
60-8 70-8
60-8 50-8
R
S
T
Power
L
L
L
1
2
3
supply
R
S
T
L
L
1
2
, L
, L
.
2
3
and L
.
1
2
INSTALLATION AND WIRING
Cables (Note 1)
mm
2
R, S, T
U, V, W
L
, L
, L
1
2
3
2-4
2
2
3.5
3.5
5.5
5.5
8-5
14
8
14
14
22
22
38
38
38
38
60
60
100
100
100
100
150
150
Cables (Note 1)
mm
2
R, S, T
U, V, W
L
, L
, L
1
2
3
2
2
3.5
2
3.5
3.5
5.5
5.5
14
8
14
8
22
14
22
22
22
22
38
38
60
60
Ground
U
V
W
terminal
Ground
U
V
W
L
3
Connect the motor to U, V, W.
In the above connection,
turning on the forward rotation
switch (signal) rotates the motor
in the counterclockwise (arrow)
direction when viewed from
the load shaft.
16
, L
, L
1
2
PVC insulated
Cables (Note 1)
AWG
mm
R, S, T
R, S, T
U, V, W
L
, L
, L
L
, L
, L
1
2
3
1
2
14
14
2.5
12
12
4
10
10
6
6
8
16
6
6
16
4
4
35
2
2
35
2
2
70
1/0
1/0
95
4/0
4/0
75
4/0
4/0
MCM300
MCM300
PVC insulated
Cables (Note 1)
AWG
mm
R, S, T
R, S, T
U, V, W
L
, L
, L
L
, L
, L
1
2
3
1
2
14
14
2.5
12
14
4
12
12
4
10
10
6
6
8
16
6
8
16
4
6
25
4
4
25
4
4
25
2
2
50
1/0
1/0
70
Motor
and
3
2
U, V,
W
3
2.5
2.5
4
6
10
16
25
35
50
70
2
U, V,
W
3
2.5
2.5
4
2 2
6
10
10
16
25
25
35
50

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents