Inboard Dedicated Options - Mitsubishi FR-F500 Instruction Manual

Transistorized inverter
Hide thumbs Also See for FR-F500:
Table of Contents

Advertisement

7.1.2 Inboard dedicated options

Inboard options
Name
12-bit digital input
FR-A5AX
Digital output
FR-A5AY
Extension analog
output
Relay output
FR-A5AR
Auxiliary Control
FR-A5AC
(Note2)
Analog input-output
function
FR-A5AN
(Note2)
Computer link
FR-A5NR
Relay output
Profibus DP
FR-A5NP
DeviceNet
FR-A5ND
TM
CC-Link (Note 3)
FR-A5NC
Modbus Plus
FR-A5NM
Note: 1. Three inboard options may be mounted at the same time (the number of the same options mountable is only one, and only one
of the communication options may be mounted.)
2. NA version only.
3. CC-Link stands for Control & Communication Link.
Type
Input interface used to set the inverter frequency accurately using external 3-digit BCD or
12-bit binary-coded digital signals.
Gains and offsets can also be adjusted.
Among standard output signals of the inverter, this option outputs any 7 selected signals
from open collector output terminals.
Outputs extra 16 signals which can be monitored on the FM and AM terminals such as
output frequency, output voltage and output current, etc.
20mADC or 5V(10V)DC meter can be connected.
Among 26 standard output signals of the inverter, this option outputs any 3 selected
signals from relay contact output terminals.
Eight 120VAC inputs which implement the input terminal functions of the inverter.
Two relay outputs which are selected from among standard outputs.
One isolated 4-20mA input which can set the frequency command to the inverter.
Two Isolated 4-20mA outputs which can be connected to an analog meter or other
compatible device.
Operation/monitoring/parameter change of the inverter can be performed under the control
of a user program from a computer, e.g. personal computer or FA controller, connected by
a communication cable.
Any one output signal can be selected from among the standard output signals of the
inverter and output as a relay contact (contactor) signal.
Operation/monitoring/parameter change of the inverter can be performed from a computer
or PLC.
Operation/monitoring/parameter change of the inverter can be performed from a computer
or PLC.
Operation/monitoring/parameter change of the inverter can be performed from a PLC.
Operation/monitoring/parameter change of the inverter can be performed from a computer
or PLC.
Function
194
OPTIONS