Mitsubishi FR-F500 Instruction Manual page 65

Transistorized inverter
Hide thumbs Also See for FR-F500:
Table of Contents

Advertisement

Parameter
Name
Number
60
Intelligent mode selection
65
Retry selection
Stall prevention operation reduction
66
starting frequency
Number of retries at alarm
67
occurrence
68
Retry waiting time
69
Retry count display erasure
71
Applied motor
72
PWM frequency selection
73
0-5V/0-10V selection
74
Filter time constant
Reset selection/disconnected PU
75
detection/PU stop selection
76
Alarm code output selection
77
Parameter write disable selection
78
Reverse rotation prevention selection
79
Operation mode selection
160
User group read selection
180
RL terminal function selection
181
RM terminal function selection
182
RH terminal function selection
183
RT terminal function selection
184
AU terminal function selection
185
JOG terminal function selection
186
CS terminal function selection
190
RUN terminal function selection
191
SU terminal function selection
192
IPF terminal function selection
193
OL terminal function selection
194
FU terminal function selection
195
A, B, C terminal function selection
240
Soft-PWM setting
244
Cooling fan operation selection
900
FM terminal calibration
901
AM terminal calibration
902
Frequency setting voltage bias
903
Frequency setting voltage gain
904
Frequency setting current bias
905
Frequency setting current gain
990
Buzzer control
Used to cause the inverter to automatically set the appropriate parameters and
perform operation.
Used to select the alarm whose occurrence will cause the inverter to reset and
retry automatically.
Used to set the number of retries to be made when an alarm occurs.
Used to set the number of retries and the waiting time.
Used to set the thermal characteristic of the electronic overcurrent protection
according to the motor used.
Used to change the motor tone.
When using the voltage-input signal to perform operation, set the specifications of
the frequency setting signal input to across terminals 2-5.
Used to set the input section built-in filter constant of an external voltage or
current frequency setting signal.
Used to choose the reset selection, disconnected PU detection and PU stop
selection functions.
Used to output a 4-bit digital signal from the open collector output terminals as the
definition of an alarm that has occurred.
Used to enable or disable the write of various parameters to prevent the
parameters from being rewritten by accidental operation.
Used to prevent reverse operation trouble due to the false input of the start signal.
Use to choose the operation mode of the inverter.
Used to read the values of the basic parameters or all parameters.
Used to choose and assign the functions of the input terminals.
Used to choose and assign the functions of the output terminals.
Used to change the motor tone.
Used to control the operation of the cooling fan incorporated in the inverter.
Used to calibrate the meters connected to terminals FM-SD and AM-5.
Used to set the magnitude (slope) of the output frequency as desired relative to
the frequency setting signal (0 to 5V, 0 to 10V or 4 to 20mA DC).
Used to produce or mute the operational sound generated when you press the
keys of the operation panel and parameter unit.
53
OPERATION/CONTROL