Program *79 - Door Phone To [Dn] Flashing Assignments - Toshiba DK14 Programming Manual

Strata dk digital business telephone
Table of Contents

Advertisement

Program *79 – Door Phone to [DN] Flashing
Assignments
Processor Type:
Program Type:
Initialized Default:
Door Box Number (1~4)
Door Box Circuit Number (1~3)
Processor Type Port Range [PhDN] Port Range
DK14
DK40i
RCTUA
RCTUBA/BB
RCTUC/D
RCTUE/F
Door Phone Number/Location
1
2
3
4
5
6
7
8
9
10
11
12
Program *79 Overview
This program assigns door phones to ring Directory Number buttons ([PDNs]/[SDNs] [PhDNs])
when pressed and flash the [DN]'s LED. Each door phone can be assigned to flash one [DN]'s
LED and the [DN] can be assigned to appear and ring on up to 120 telephones.
Program 79 must be used in conjunction with Program *79 to ring a telephone with a flashing
[DN], when the door phone button is pressed. See Program 77-1 for door phone control box port
assignments.
Important!
To allow a door phone to flash and ring, you must assign the [DN] to flash in
Program *79 and the telephone on which it appears must be assigned to ring in
Program 79.
Strata DK Programming
5/00
DK14, DK40i, all RCTUs and BCUs
Station
No [DNs] assigned to ring for any door phone
000~009
500~509
000~027
500~527
000~031
500~531
000~079
500~579
000~239
500~739
000~335
500~835
Door Phone Box
Number
1
2
3
4
Program *79 – Door Phone to [DN] Flashing Assignments
Enter a [DN] Port Reference
(Port Number of the [DN] that should flash when the door phone
button is pressed.) [DN] = [PDN] or [PhDN] port (see Legend
below)
Processor Type Port Range [PhDN] Port Range
B1CU
000~055
B2CAU/BU
000~111
B3CAU/BU
000~191
B5CAU/BU
000~335
Door Box Circuit
Number
1
2
3
1
2
3
1
2
3
1
2
3
System & Station
500~579
500~739
500~739
500~835
[DN] Port Reference
Number
3-177