Program 34 - Hold Recall Timing - Toshiba DK14 Programming Manual

Strata dk digital business telephone
Table of Contents

Advertisement

Program 34 – Hold Recall Timing
Processor Type:
Program Type:
Initialized Default:
SELECT = Station Logical Port Number
Enter the port number having its Hold
Recall Time defined.
To add a port range, enter XXX✱XXX
(low port ✱ high port).
Processor Type
DK14
DK40i
RCTUA
RCTUBA/BB
RCTUC/D
RCTUE/F
Port
Seconds
Program 34 Overview
Each station can have a different time (from 011 to 160 seconds) from the point of placing a call on
hold to the point of recall. Initialized data assigns a recall time of 032 seconds to all ports.
Strata DK Programming
5/00
DK14, DK40i, all RCTUs and BCUs
Station
Assigns a Hold Recall Time of 032 seconds to all ports
Port Range
000~009
000~027
000~031
000~079
000~239
000~335
Port
Seconds
Program 34 – Hold Recall Timing
HOLD TIME = Seconds
Enter the number of seconds the system will
wait (three digits).
Enter 000 for no Hold Recall. Enter 011~160 for
11 to 160 seconds.
Processor Type
Port Range
B1CU
000~055
B2CAU/BU
000~111
B3CAU/BU
000~191
B5CAU/BU
000~335
Port
Seconds
System & Station
Port
Seconds
3-97