Program 76-1(X-Y) - Dk14, Dk40I, All Rctus And Bcus - Toshiba DK14 Programming Manual

Strata dk digital business telephone
Table of Contents

Advertisement

System & Station
Program 76-1(X-Y) – DK14, DK40i, all RCTUs and BCUs
Program 76-1(X-Y) – DK14, DK40i, all RCTUs and BCUs
Processor Type:
Program Type:
Initialized Default:
Program 76-1 Overview
This program assigns each installed WSIU (DK14 only), TSIU (DK40i only) or RSIU/RSIS
(DK424 only) port to a function.
For Program 76-1(X-Y):
X identifies the WSIU, TSIU port number 1~2 or RSIU/RSIS/RMDS port number 1~4.
Y identifies the WSIU, TSIU or RSIU/RSIS/RMDS port function as shown below:
Port Type (Y)
0
1
2
3
4
5
6
1. If port type code 1 is set, then Program 77-1, LED 14 status determines if the port operates as a system administration/
maintenance modem (LED 14 On) or an RS-232 administration/maintenance TTY port (LED 14 Off). For modem
operation, an RMDS piggy-back PCB is required, for RS-232 TTY port, a TSIU, WSIU, RSIU/RSIS/RMDS PCB
may be used.
2. If the DK14 CO lines must pass Caller ID information to the Toshiba telephones, LCD/RPCI-DI, an interface box,
TC1041 (MLX-41), must be connected to one of the WSIU outputs. For more information, see the Caller ID
instructions in Chapter 1 – DK14 Installation of the Strata DK I&M Manual.
o
Port types set in this program override RSSU, PIOU, and/or PIOUS function codes (41, 42,
43) set in Program 03. To activate changes made to this program, system power must be turned
off/on or Program 91-2 must be run.
o
Communication Parameters: SMDI, MIS or SMIS, TTY, IMDU/RMDS, Caller ID, OAI: 7
bits, even parity, 1 stop bit. SMDR: 8 bits, no parity, 1 stop bit.
3-162
DK14, DK40i, all RCTUs and BCUs
System
Port 1 (Type 1), Ports 2~4 (Type 0)
SELECT = 1
X = Port Number (1~4)
Y=Port Type (0~6), see table below.
Port Number
1
2
3
4
No port equipped. This should be used for any of the four RSIU/RSIS/RMDS ports that are not used.
1
TTY or modem
.
TTY RS-232 port (set Program 77-1, LED 14 Off; DK14, DK40i, DK424 or DK424i).
RMDS modem port (set Program 77-1, LED 14 On; DK424 or DK424i).
SMDR
MIS or SMIS (DK424)
SMDI
Open Architecture Interface (see Program 77-4) (DK424 R3.2)
Caller ID output to Caller ID interface box (DK14 only)
Run Program 91-2
System power must be cycled or Program 91-2
must be run to transfer Program 76-1 data entries
from temporary memory to working memory.
Port Type (0~6)
Function
2
Strata DK Programming
5/00

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dk40iDk424Dk424i

Table of Contents