Reassign An Interface To A New Port Channel - Dell Force10 C150 Configuration Manual

Ftos configuration guide ftos 8.4.2.7 e-series terascale, c-series, s-series (s50/s25)
Hide thumbs Also See for Force10 C150:
Table of Contents

Advertisement

Figure 20-15. Error Message
FTOS(conf-if-portch)#show config
!
interface Port-channel 5
no ip address
switchport
channel-member GigabitEthernet 1/6
FTOS(conf-if-portch)#int gi 1/6
FTOS(conf-if)#ip address 10.56.4.4 /24
% Error: Port is part of a LAG Gi 1/6.
FTOS(conf-if)#

Reassign an interface to a new port channel

An interface can be a member of only one port channel. If the interface is a member of a port channel, you
must remove it from the first port channel and then add it to the second port channel.
Each time you add or remove a channel member from a port channel, FTOS recalculates the hash
algorithm for the port channel.
To reassign an interface to a new port channel, use these commands in the following sequence in the
INTERFACE mode of a port channel:
Step
Command Syntax
no channel-member
1
interface port-channel id
2
channel-member
3
Figure 20-16
displays an example of moving the GigabitEthernet 1/8 interface from port channel 4 to port
channel 3.
Command Mode
INTERFACE
interface
PORT-CHANNEL
INTERFACE
number
PORT-CHANNEL
INTERFACE
interface
PORT-CHANNEL
Error message
Purpose
Remove the interface from the first port
channel.
Change to the second port channel
INTERFACE mode.
Add the interface to the second port channel.
Interfaces | 433