Show Interfaces Configured - Dell Force10 C150 Configuration Manual

Ftos configuration guide ftos 8.4.2.7 e-series terascale, c-series, s-series (s50/s25)
Hide thumbs Also See for Force10 C150:
Table of Contents

Advertisement

Figure 20-1. show interfaces Command Example
FTOS#show interfaces tengigabitethernet 1/0
TenGigabitEthernet 1/0 is up, line protocol is up
Hardware is Force10Eth, address is 00:01:e8:05:f3:6a
Current address is 00:01:e8:05:f3:6a
Pluggable media present, XFP type is 10GBASE-LR.
Medium is MultiRate, Wavelength is 1310nm
XFP receive power reading is -3.7685
Interface index is 67436603
Internet address is 65.113.24.238/28
MTU 1554 bytes, IP MTU 1500 bytes
LineSpeed 10000 Mbit, Mode full duplex, Master
ARP type: ARPA, ARP Timeout 04:00:00
Last clearing of "show interface" counters 00:09:54
Queueing strategy: fifo
Input Statistics:
0 packets, 0 bytes
0 Vlans
0 64-byte pkts, 0 over 64-byte pkts, 0 over 127-byte pkts
0 over 255-byte pkts, 0 over 511-byte pkts, 0 over 1023-byte pkts
0 Multicasts, 0 Broadcasts
show ip interfaces brief
Use the
enabled for Layer 3 data transmission. In
since an IP address has been assigned to it and the interface's status is operationally up.
Figure 20-2. show ip interfaces brief Command Example (Partial)
FTOS#show ip interface brief
Interface
GigabitEthernet 1/0
GigabitEthernet 1/1
GigabitEthernet 1/2
GigabitEthernet 1/3
GigabitEthernet 1/4
GigabitEthernet 1/5
GigabitEthernet 1/6
GigabitEthernet 1/7
GigabitEthernet 1/8

show interfaces configured

Use the
interfaces. In
Figure
20-2, GigabitEthernet interface 1/5 is in Layer 3 mode since an IP address has been
assigned to it and the interface's status is operationally up.
To determine which physical interfaces are available, use the
mode. This command displays all physical interfaces available on the line cards.
command in the EXEC Privilege mode to view which interfaces are
Figure
20-2, GigabitEthernet interface 1/5 is in Layer 3 mode
IP-Address
OK? Method Status
unassigned
NO
Manual administratively down down
unassigned
NO
Manual administratively down down
unassigned
YES Manual up
unassigned
YES Manual up
unassigned
YES Manual up
10.10.10.1
YES Manual up
unassigned
NO
Manual administratively down down
unassigned
NO
Manual administratively down down
unassigned
NO
Manual administratively down down
command in the EXEC Privilege mode to view only configured
Protocol
up
up
up
up
show running-config
command in EXEC
(Figure
158).
Interfaces | 417

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents