Event, Error, and Warning Messages
EFI Error and Warning Messages
Table B-1
EFI Error and Warning Messages (Continued)
Error
Number
58
Checksum error accessing FRU information
59
FRU information version error

SEL and FPL Log Entries

This section is a quick reference for the intelligent platform management interface (IPMI) events recorded in the SEL and FPL
files. These logs are available via the management processor (MP) card interface or the BMC command line interface (CLI).
All entries from the SEL are forwarded to the FPL. The FPL is a circular log so the newest entries replace the oldest. The
FPL contains forward progress messages from the BMC, System firmware, EFI, and the OS.
The SEL will not accept new entries once it is full and contains only those events considered of major importance to
system operation.
Both contain type 02 and E0 messages.
A triplet is formed from the SensorType, EventType, and the lower nibble of the Data1 fields of Type 02 events. MP
firmware displays the triplet in the Keyword field.
NOTE
Systems with firmware version 2.0 or higher also have a clearlogs command that will clear out the log
files should they become full.
Accessing the logs with BMC CLI commands
The cli>sl -f command displays the forward progress log. For example:
Rec#
Sev Generator/Sensor Description
-------- - ---------------- ------------ ----------- --------------------------
00000000 - BMC
00000002 - BMC
00000003 - ACPI State
00000004 - Fan 1 (PSU)
00000005 - Fan 2 (Mem)
00000006 - SFW
00000007 2 CPU1
00000008 2 CPU1
00000009 0 CPU1
196
Error/Warning Message
Event ID
Chass cntrl
00-12:70:A3 81:03
LPC reset
00-12:70:02
S0 (on)
FA-22:6F:00
OK
11-0A:07:00
OK
12-0A:07:00
Boot start
00-1D:0A:00
Boot start
00063
Boot start
00063
00020
Replace the FRU which was reported. If the error
message is repeated, contact the HP Support
center for assistance.
Replace the FRU which was reported. If the error
message is repeated, contact the HP Support
center for assistance.
Data, Timestamp
2003-10-31 22:41:29
2003-10-31 22:41:30
2003-10-31 22:41:31
2003-10-31 22:41:31
2003-10-31 22:41:31
2003-10-31 22:41:32
DT 04
0000000000000000
Time
2003-10-31 22:41:32
DT 00
0000000000000000
Solution
Appendix B