Removing And Replacing The Optional Management Processor Card Battery; Removing The Optional Management Processor Card Battery; Replacing The Optional Management Processor Card Battery; Figure 7-43Location Of Management Processor Battery - HP Integrity rx1600 Operation And Maintenance Manual

Rsvla-0302
Hide thumbs Also See for Integrity rx1600:
Table of Contents

Advertisement

Removing and Replacing Components

Removing and Replacing the Optional Management Processor Card Battery

Removing and Replacing the Optional Management Processor Card Battery
Systems with an optional management processor card have two batteries. Systems with no management processor card have
only one battery. The main system battery is located on the system board. The management processor battery is located on the
management processor card. The battery is 3.3 vdc, BR-type with 250 mAh.

Removing the Optional Management Processor Card Battery

Step
1. Perform all of the steps described in the procedure for Removing the Optional Management Processor Card.
Step
2. The battery for the management processor is located on the bottom of the card.

Figure 7-43Location of Management Processor Battery

Step
3. Lift up on the battery and push on the back of it with a flat-head screwdriver to remove the battery from its holder.
CAUTION

Replacing the Optional Management Processor Card Battery

Step
1. Lift up on the battery holder retaining clip with a flat-head screwdriver and slide the battery into the holder. The
positive (+) terminal of the battery faces up.
170
Only lift the battery high enough to clear the holder. Excessive stress on the battery holder
retaining clip may damage the clip.
Chapter 7

Advertisement