Step
3. Close the drive-ejector handle by pushing it down until it clicks.
Figure 7-36Hard Disk Drive Installation
Step
4. The disk drive is now correctly installed.
Removing and Replacing the Power Supply
The power supply is located at the left front of the server chassis. The power supply is a field replaceable unit (FRU).
WARNING
Ensure that the system is powered-down and all power sources have been disconnected from the server
prior to removing or replacing the power supply.
Voltages are present at various locations within the server whenever an AC power source is connected.
This voltage is present even when the main power switch is in the off position.
Failure to observe this warning could result in personal injury or damage to equipment.
CAUTION
Observe all ESD safety precautions before attempting this procedure. Failure to follow ESD safety
precautions could result in damage to the server.
Removing the Power Supply
To remove the power supply, perform the following steps:
Chapter 7
Removing and Replacing Components
Removing and Replacing the Power Supply
163