BOOT_LOAD_FW_ADDR
SFW
1,1,0,0,0
BOOT_LOAD_FW_MODULE
PDHC
1,1
ELS_START_PARTITION
14:26:50
OA
1,1
ELS_OA_SAVE_RECOV_FILE
14:26:50
SEL and FPL viewers
Both the SEL and FPL viewers provide a way for OA users to view stored event records. The OA
supports multiple simultaneous viewers. The maximum number of viewers is limited by the number of
connections supported by the OA. Each viewer works independently from any other viewer, meaning
each viewer can select its own filter options without affecting other viewers.
The logs can be filtered using the following items:
•
blade number
•
cabinet number (not applicable for this release)
•
partition number
•
alert level
The following format options are also available:
•
Keyword—This is the default format for all viewers. The keyword format supplies the following
information about an event:
◦
log number
◦
reporting entity type
◦
reporting entity ID
◦
alert level
◦
hexadecimal dump of event records
◦
event ID keyword
•
Raw hex—The raw hex format supplies the following information about an event:
◦
hexadecimal dump of event records
•
Text—The text format supplies the following information about an event:
◦
log number
◦
timestamp
◦
alert level
◦
event ID keyword
◦
brief text description
◦
reporting entity type
◦
reporting entity ID
◦
hexadecimal dump of event records
•
Problem/Cause/Action—The Problem/Cause/Action format displays the problem/cause/action
statement in addition to the summary and other fields displayed by the text format.
NOTE:
The display of column headers can be turned on or off using toggle option C. By default, the column
header will be on.
To connect to the FPL viewer, enter the SHOW FPL command on the Monarch OA.
1
0 0900232401e10000 652e6c7049657844
1
1 36801df200e10000 0000000000000000
None
0 168024b600e10000 0000000000000000
03/17/2014
03/17/2014
SEL and FPL viewers
75