Sel And Fpl Log Entries - HP Integrity rx1620 Operation Manual

Hide thumbs Also See for Integrity rx1620:
Table of Contents

Advertisement

Event, Error, and Warning Messages
EFI Error and Warning Messages
Table A-1
EFI Error and Warning Messages (Continued)
Error
Number
53
Error building SMBIOS
54
Failure constructing the EFI Memory Data
Table (MDT)
55
Universal Unique IDentifier (UUID) error
56
Error reading CPU SMBIOS information ROM
57
Error accessing Field Replaceable Unit (FRU)
information
58
Checksum error accessing FRU information
59
FRU information version error

SEL and FPL Log Entries

This section is a quick reference for the intelligent platform management interface (IPMI) events recorded in
the SEL and FPL files. These logs are available via the management processor (MP) card interface or the
BMC command line interface (CLI).
All entries from the SEL are forwarded to the FPL. The FPL is a circular log so the newest entries replace
the oldest. The FPL contains forward progress messages from the BMC, System firmware, EFI, and the
OS.
The SEL will not accept new entries once it is full and contains only those events considered of major
importance to system operation.
Both contain type 02 and E0 messages.
A triplet is formed from the SensorType, EventType, and the lower nibble of the Data1 fields of Type 02
events. MP firmware displays the triplet in the Keyword field.
Systems with firmware version 2.0 or higher also have a clearlogs command that will clear
NOTE
out the log files should they become full.
Accessing the logs with BMC CLI commands
The cli>sl -f command displays the forward progress log. For example:
Rec#
Sev Generator/Sensor Description
-------- - ---------------- ------------ ----------- --------------------------
114
Error/Warning Message
Event ID
Contact the HP Support center for
assistance.
Contact the HP Support center for
assistance.
Update with sysset command.
Reboot the server. If the error message is
repeated, replace the failing processor.
Replace the FRU which was reported. If
the error message is repeated, contact the
HP Support center for assistance.
Replace the FRU which was reported. If
the error message is repeated, contact the
HP Support center for assistance.
Replace the FRU which was reported. If
the error message is repeated, contact the
HP Support center for assistance.
Data, Timestamp
Solution
Appendix A

Advertisement

Table of Contents
loading

This manual is also suitable for: