HP Integrity rx1600 Operation And Maintenance Manual page 113

Rsvla-0302
Hide thumbs Also See for Integrity rx1600:
Table of Contents

Advertisement

Table 6-18
Processor Faults
System
LED 1
LED
Flashing
Red
Red
Flashing
Red
Red
Flashing
Red
Red
Table 6-19
BMC Faults
System
LED 1
LED
Flashing
Red
Red
Flashing
Red
Red
Table 6-20
Temperature Faults
System
LED 1
LED
Flashing
Red
Red
Table 6-21
Power Supply Errors
System
LED 1
LED
Flashing Red
Off
Flashing Red
Green
Chapter 6
LED 2
LED 3
Red
Green
Off
Red
Off
Green
Red
Green
Green
LED 2
LED 3
Green
Red
Green
Red
LED 2
LED 3
Green
Green
LED 2
LED 3
Red
Off
Red
Off
Identifying and Diagnosing Hardware Problems
LED 4
Problem
Processor 0
temperature
exceeds limit
Processor 1
temperature
exceeds limit
No processor
detected.
LED 4
Problem
Off
BMC
firmware is
damaged
Green
System board
FRU inventory
device
inaccessible
LED 4
Problem
Red
External air
temperature
too high
LED 4
Problem
Red
VRM or power pod
fault
Red
Power Supply fault
Troubleshooting
Solution
Make sure nothing is blocking the
system's airflow and locate your
system in an air-conditioned room. In a
single CPU configuration, verify that
the airflow blocker is installed.
Verify that the processor or processors
are correctly installed. See Chapter 4,
Installing and Configuring, for
installation procedures.
Solution
Turn off and unplug the system. Wait
20 seconds, then plug in and restart the
system. If the error repeats, replace the
base unit.
Replace the base unit.
Solution
Make sure nothing is blocking the
system's airflow and locate your
system in an air-conditioned room.
Solution
View the SEL for additional
information.
View the SEL for additional
information. Replace the power
supply if necessary.
115

Advertisement

Table of Contents
loading