Sel And Fpl Log Entries; Accessing The Logs With Bmc Cli Commands - HP Integrity cx2600 Maintenance Manual

Hp integrity cx2600 operations and maintenance guide
Hide thumbs Also See for Integrity cx2600:
Table of Contents

Advertisement

Previous boot
Live events
Clear SEL/FPL logs
5.
Select the desired log for viewing. (For additional information about the management
processor and all commands refer to

SEL and FPL Log Entries

This section is a quick reference for the IPMI events recorded in the SEL and FPL files. These
logs are available via the MP card interface or the BMC CLI.
All entries from the SEL are forwarded to the FPL. The FPL is a circular log so the newest
entries replace the oldest. The FPL contains forward progress messages from the BMC,
System firmware, EFI, and the operating system.
The SEL will not accept new entries once it is full and contains only those events considered
of major importance to system operation.
Both contain type 02 and E0 messages.
A triplet is formed from the SensorType, EventType, and the lower nibble of the Data1
fields of Type 02 events. MP firmware displays the triplet in the Keyword field.

Accessing the Logs With BMC CLI Commands

The fpl command displays the forward progress log. For example:
Type
1
02
0000000E -
E0
0000000F 2
E0
00000010 2
E0
00000011 0
E0
00000012 0
E0
00000013 1
E0
00000014 1
E0
00000015 0
E0
00000016 0
E0
00000017 0
E0
00000018 0
02
00000019
The sel command displays the system event log. For example:
Type
1
2
7
02
00E0 - Pwr Spply 1 Ctrl Enabled 44-08:09:01 2003-02-28 16:41:46
E0
00F0 2 CPU0 Boot start 00063 DT 06 0000000000000000
E0
0100 2 CPU0 Boot start 00063 Time 2003-02-28 16:41:46
02
0110 - BMC LPC reset 00-12:70:02 2003-02-28 16:41:47
Each column in the log contains a different data field:
1
Record ID
2
Severity for E0 messages
3
Generator ID or sensor reporting the event
4
Text description of events
5
Sensor number - Sensor Type: Event Type: Data1 fields for type 02 messages (triplet) event
ID for E0 messages
6
Data2 and Data3 for type 02 messages (if applicable) or data type for E0 messages
7
Timestamp or extended data specific to the event
2
3
4
Pwr Spply 1 Ctrl Enabled 44-08:09:01 2003-02-28 16:41:46
CPU0 Boot start 00063 DT 06 0000000000000000
CPU0 Boot start 00063 Time 2003-02-28 16:41:46
CPU0 00020 DT 00 0000000000000000
CPU0 0000E DT 06 0000000000010000
CPU0 CPU monarch 0000C DT 06 0000000000000000
CPU0 CPU present 00261 DT 06 0000000000000000
CPU0 00008 DT 00 0000000000000000
CPU0 0024B DT 00 0000000000000000
CPU0 00006 DT 03 0000000000000000
CPU0 00044 DT 06 02000000002C0400
-
BMC LPC reset 00-12:70:02 2003-02-28 16:41:47
3
"Utilities" (page
73))
5
4
6
7
5
6
Error Messages