Smart Array (A9890A) Cable Routing
The purpose of this document is to provide cable routing information when a Smart Array PCI-X RAID card (A9890A)
is used to drive the embedded hard disk drives. The existing SCSI cable connected to the Channel A connector on the
system board is relocated to the Channel A connector on the Smart Array PCI-X card installed in slot 1 (full-length slot)
of the PCI cage.
The SCSI cable is routed from the PCI cage under the power supply bracket and over the IDE cable, if installed, avoiding
blocking the airflow of the chassis fans.
Refer to the hp integrity rx1600 Operation and Maintenance Guide for detailed instructions on powering down the
server, extending the server from a rack, and removing and replacing covers and components.
1. Disconnect the SCSI cable from the Channel A connector on the system board by pulling on the cable release strap.
See figure 1.
NOTE
If an optional management processor card is installed in the server, follow the
instructions provided in the hp integrity rx1600 Operation and Maintenance Guide to
remove the card, allowing access to the Channel A connector. Reinstall the card after the
SCSI cable has been disconnected.
2. Remove the PCI cage from the server.
3. Remove any accessory card installed in PCI slot 2 (half-length slot).
4. Install the Smart Array PCI-X RAID card (A9890A) in PCI slot 1 (full-length slot).
5. Orient the PCI cage with the installed PCI-X RAID card component-side-up allowing routing of the SCSI cable.
See figure 2.
Exit parallel to
connector
v1
February 2004
Printed in the U.S.A.
Figure 1. SCSI Channel A Connector on System Board
Figure 2. Cable Routing on Smart Array Card and PCI Cage
Under slot 2 connector
Channel A1
Channel A
connector
Around heatsink

Advertisement

loading

Summary of Contents for HP Integrity rx1600

  • Page 1 The SCSI cable is routed from the PCI cage under the power supply bracket and over the IDE cable, if installed, avoiding blocking the airflow of the chassis fans. Refer to the hp integrity rx1600 Operation and Maintenance Guide for detailed instructions on powering down the server, extending the server from a rack, and removing and replacing covers and components.
  • Page 2 Do not block the airflow of the chassis fans. Reduced airflow may cause overheating. 13. Complete the installation by following the instructions provided in the hp integrity rx1600 Operation and Maintenance Guide for closing up the server, installing in a rack, and powering-up. To enable RAID refer to the...