Extreme Networks Summit WM Technical Reference Manual page 71

Version 5.1
Hide thumbs Also See for Summit WM:
Table of Contents

Advertisement

Table 19: Summit WM Controller WM200/2000 application states (Continued)
Condition
Error LED
Failed to identify FDD. Possibly
due to removal of FDD card.
• Activity LED = Enabled
• Warning LED = Enabled
• Error LED = Enabled
• SSD= 1
Failed to initialize NPE card.
• Activity LED = Enabled
• Warning LED = Enabled
• Error LED = Enabled
• SSD= 2
Critical threshold reached (95C
for NPE). System will reboot.
• Activity LED = Enabled
• Warning LED = Enabled
• Error LED = Enabled
• SSD= 3
Full fan assembly failure (both
trays). System will reboot.
• Activity LED = Enabled
• Warning LED = Enabled
• Error LED = Enabled
• SSD= 4
Application initialization failure.
Startup manager failed to
initialize all of system's
components. system will
reboot.
• Activity LED = Enabled
• Warning LED = Enabled
• Error LED = Enabled
• SSD= 5
Lost connectivity with FE.
Possible failure of NPE card.
System will reboot.
• Activity LED = Enabled
• Warning LED = Enabled
• Error LED = Enabled
• SSD= 6
Summit WM Technical Reference Guide, Software Version 5.1
Log
Level
Comment
Action
Re-insert card. If card
present, contact
Technical Support to
arrange replacement.
Re-insert card. If card
present, contact
Technical Support to
arrange replacement.
Check speed/state for
fans. Check for proper
airflow access. If
problem persists,
contact Technical
Support.
Re-insert fan tray. If
card present, contact
Technical Support to
arrange replacement.
If problem persists,
contact Technical
Support.
Investigate failure
condition in
/var/controller/
log/logs/
ixcapture.log
If problem persists,
contact Technical
Support.
71

Advertisement

Table of Contents
loading

Table of Contents