Extreme Networks Summit WM Technical Reference Manual page 195

Version 5.1
Hide thumbs Also See for Summit WM:
Table of Contents

Advertisement

Table 46: REMOTE_INS (58) logs and events (Continued)
Log ID
Log Message
Unable to initialize signal
handlers
Unable to initialize internal
configuration data structures
Unable to initialize global log
bitmask
Major
9
%s
Threat [Known AP with invalid
SSID] detected by AP%s,
SN%s (%s). Details: RSSI:%u,
scanned channel:%u,
channel_rx:%u, bssid:%s,
ssid:%s, privacy:%s,
bssType:%s,
beaconInterval:%dms
Threat [Device in ad-hoc mode]
detected by AP%s, SN%s (%s).
Details: RSSI:%u, scanned
channel:%u, channel_rx:%u,
bssid:%s, ssid:%s, privacy:%s,
bssType:%s,
beaconInterval:%dms
Error in analysis_threads:
empty command arguments.
Thread will exit
Error in analysis_thread: failed
to connect to db message
queue. Thread will exit
Error in setting up RFDC
connection: cannot initialize
pthread attributes. Connection
cannot be setup.
Error in setting up RFDC
connection: cannot set
detached pthread attributes.
Connection cannot be setup.
Summit WM Technical Reference Guide, Software Version 5.1
Comment
Internal operation error. May
indicate a larger problem with
system's memory resource
management.
Internal operation error. May
indicate a larger problem with
system's memory resource
management.
Internal operation error. May
indicate a larger problem with
system's memory resource
management.
Scan Result indication
Scan Result indication
Internal operation error. Thread
exist shall cause component to
terminate and be automatically
started by system's health
monitor facility. Situation
should repair itself.
Internal operation error. Thread
exist shall cause component to
terminate and be automatically
started by system's health
monitor facility. Situation
should repair itself.
Internal operation error.
Problem may prevent Rogue AP
(Summit WM series Spy)
detection from taking place.
Component may need to be
restarted.
Internal operation error.
Problem may prevent Rogue AP
(Summit WM series Spy)
detection from taking place.
Component may need to be
restarted.
Action
If problem persists Contact
Technical Support for
investigation.
If problem persists Contact
Technical Support for
investigation.
If problem persists Contact
Technical Support for
investigation.
Take appropriate remedial
action to identify and
neutralize threat.
Take appropriate remedial
action to identify and
neutralize threat.
If problem persists Contact
Technical Support for
investigation.
If problem persists Contact
Technical Support for
investigation.
If problem persists Contact
Technical Support for
investigation.
If problem persists Contact
Technical Support for
investigation.
195

Advertisement

Table of Contents
loading