HP StorageWorks 1510i - Modular Smart Array User Manual page 42

Active/active firmware v2.0 or later
Hide thumbs Also See for StorageWorks 1510i - Modular Smart Array:
Table of Contents

Advertisement

1.
If desired, use the instructions on the provided rack template to mark the holes on the front and
rear rack uprights that will be used by the rails.
2.
If the holes in the rack uprights are round instead of square, remove the standard pins from the rails
and replace them with the provided smaller round-hole pins.
CAUTION:
Pins in the rails are load-bearing. Do not remove the standard pins except to replace them
with the smaller pins for round-hole racks.
3.
Identify the left (L) and right (R) rack rails by markings stamped into the rails.
42
Installation