66 CACHE HARDWARE
FAILED AND
DISABLED
67 CACHE HARDWARE
TEMPORARILY
DISABLED
68 OBSOLETE CACHE
DATA DELETED
69 CACHE BATTERIES
LOW, RECHARGING
70 CACHE DISABLED
NO CONFIGURATION
Type
Description
The cache memory has
Error
experienced a hardware failure.
The cache memory hardware
has temporarily been disabled,
typically because the battery is not
Informational
charged or a capacity expansion
operation is occurring. The cache
automatically enabled once the
condition has been corrected.
Old data that no longer belongs
to any current configured volumes
was found in the cache memory
Informational
at power up. This data has been
deleted. This typically happens
if cache modules are moved
between array controllers.
The batteries on the cache module
Informational
are low and are being recharged.
The cache has not been configured
and is disabled. The cache is
configured using the Storage
Informational
Management Utility (SMU) or
MSA Command Line Interface
(MSA-CLI).
1510i Modular Smart Array installation and user guide
Action
If the failure has occurred on the
standby array controller, remove
the standby array controller,
replace the cache modules, wait
10 seconds, and then reinsert the
array controller, ensuring that it is
fully seated in the chassis.
If the failure has occurred on the
active array controller, wait until
downtime is available. Power
off the MSA, remove the array
controller, replace the cache
modules, and reinsert the array
controller, ensuring it is fully seated
in the chassis.
Should the issue persist, contact
HP support.