HP StorageWorks 1510i - Modular Smart Array User Manual page 121

Active/active firmware v2.0 or later
Hide thumbs Also See for StorageWorks 1510i - Modular Smart Array:
Table of Contents

Advertisement

Message
150 BEACON ON
151 BEACON OFF
201 ARRAY
CONTROLLER
TEMPERATURE OK
202 ARRAY
CONTROLLER
OVERHEATING
203 ARRAY
CONTROLLER
OVERHEATED
204 ARRAY
CONTROLLER
DISABLED
205 ARRAY
CONTROLLER
RESTARTING
300 RECOVERY ROM
AUTOFLASH STARTED
Type
Description
The LEDs on the MSA and all
connected hard drives are blinking
because that array controller
Informational
was selected for identification
or configuration in a host-based
application such as the ACU or
SMU.
The LEDs on the MSA and all
connected hard drives are no
longer blinking because the
Informational
host-based application is no longer
identifying or configuring this
MSA.
The temperature sensor on the
array controller indicates that the
temperature that was previously
Informational
exceeding the normal operating
range is now back within the
range.
The temperature sensor on the
array controller indicates that
Error
the array controller is starting
to exceed the normal operating
range.
The temperature sensor on the
array controller indicates that the
Error
array controller has exceeded the
safe operating range.
The array controller has been
Error
disabled due to a redundancy
failure.
The array controller has completed
Informational
firmware cloning and is being
restarted automatically.
The array controller has detected
that the firmware's backup
recovery ROM image is invalid
Informational
and is copying the current active
firmware image into the backup
recovery ROM.
1510i Modular Smart Array installation and user guide
Action
Check all MSA fans and ensure
they are operating. Any failed
fan should be replaced. Ensure
that there is a module or blanking
panel (cover plate) in all MSA
chassis bays and slots. Empty
bays affect the airflow and cooling
ability of the MSA.
The MSA should be powered
off as soon as possible to avoid
hardware failure.
Check all MSA fans and ensure
they are operating. Any failed
fan should be replaced. Ensure
that there is a module or blanking
panel (cover plate) in all MSA
chassis bays and slots. Empty
bays affect the airflow and cooling
ability of the MSA.
Remove the disabled array
controller, wait 10 seconds, and
then reinsert the array controller,
ensuring that it is fully seated in
the chassis.
If the issue persists, contact HP
support.